2026-05-14T10:08:21.066Z|00001|vlog|INFO|opened log file /var/log/openvswitch/ovs-vswitchd.log 2026-05-14T10:08:21.076Z|00002|ovs_numa|INFO|Discovered 16 CPU cores on NUMA node 0 2026-05-14T10:08:21.076Z|00003|ovs_numa|INFO|Discovered 1 NUMA nodes and 16 CPU cores 2026-05-14T10:08:21.076Z|00004|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connecting... 2026-05-14T10:08:21.076Z|00005|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connected 2026-05-14T10:08:21.085Z|00006|bridge|INFO|ovs-vswitchd (Open vSwitch) 3.3.4 2026-05-14T10:08:28.015Z|00007|dpif_netlink|INFO|Datapath dispatch mode: per-cpu 2026-05-14T10:08:28.015Z|00008|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2026-05-14T10:08:28.016Z|00009|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2026-05-14T10:08:28.016Z|00010|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2026-05-14T10:08:28.016Z|00011|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2026-05-14T10:08:28.016Z|00012|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2026-05-14T10:08:28.016Z|00013|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2026-05-14T10:08:28.016Z|00014|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2026-05-14T10:08:28.016Z|00015|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2026-05-14T10:08:28.016Z|00016|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2026-05-14T10:08:28.016Z|00017|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 1 2026-05-14T10:08:28.016Z|00018|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2026-05-14T10:08:28.016Z|00019|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2026-05-14T10:08:28.016Z|00020|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2026-05-14T10:08:28.016Z|00021|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2026-05-14T10:08:28.016Z|00022|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2026-05-14T10:08:28.016Z|00023|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2026-05-14T10:08:28.016Z|00024|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2026-05-14T10:08:28.016Z|00025|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2026-05-14T10:08:28.016Z|00026|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2026-05-14T10:08:28.016Z|00027|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2026-05-14T10:08:28.016Z|00028|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2026-05-14T10:08:28.016Z|00029|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2026-05-14T10:08:28.017Z|00030|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 16, setting n-revalidator-threads to 5 2026-05-14T10:08:28.017Z|00031|ofproto_dpif_upcall|INFO|Starting 21 threads 2026-05-14T10:08:28.163Z|00032|bridge|INFO|bridge br-int: added interface br-int on port 65534 2026-05-14T10:08:28.164Z|00033|bridge|INFO|bridge br-int: using datapath ID 0000b2da02a1da54 2026-05-14T10:08:28.164Z|00034|connmgr|INFO|br-int: added service controller "punix:/var/run/openvswitch/br-int.mgmt" 2026-05-14T10:08:31.168Z|00035|memory|INFO|199152 kB peak resident set size after 10.1 seconds 2026-05-14T10:08:31.169Z|00036|memory|INFO|handlers:16 idl-cells-Open_vSwitch:101 ports:1 revalidators:5 rules:4 2026-05-14T10:19:50.505Z|00037|bridge|INFO|bridge br-int: deleted interface br-int on port 65534 2026-05-14T10:19:51.630Z|00001|vlog|INFO|opened log file /var/log/openvswitch/ovs-vswitchd.log 2026-05-14T10:19:51.641Z|00002|ovs_numa|INFO|Discovered 16 CPU cores on NUMA node 0 2026-05-14T10:19:51.641Z|00003|ovs_numa|INFO|Discovered 1 NUMA nodes and 16 CPU cores 2026-05-14T10:19:51.641Z|00004|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connecting... 2026-05-14T10:19:51.641Z|00005|fatal_signal|WARN|terminating with signal 15 (Terminated) 2026-05-14T10:19:51.782Z|00001|vlog|INFO|opened log file /var/log/openvswitch/ovs-vswitchd.log 2026-05-14T10:19:51.792Z|00002|ovs_numa|INFO|Discovered 16 CPU cores on NUMA node 0 2026-05-14T10:19:51.792Z|00003|ovs_numa|INFO|Discovered 1 NUMA nodes and 16 CPU cores 2026-05-14T10:19:51.792Z|00004|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connecting... 2026-05-14T10:19:51.792Z|00005|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connected 2026-05-14T10:19:51.799Z|00006|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2026-05-14T10:19:51.799Z|00007|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2026-05-14T10:19:51.799Z|00008|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2026-05-14T10:19:51.799Z|00009|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2026-05-14T10:19:51.799Z|00010|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2026-05-14T10:19:51.799Z|00011|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2026-05-14T10:19:51.799Z|00012|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2026-05-14T10:19:51.800Z|00013|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2026-05-14T10:19:51.800Z|00014|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2026-05-14T10:19:51.800Z|00015|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 1 2026-05-14T10:19:51.800Z|00016|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2026-05-14T10:19:51.800Z|00017|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2026-05-14T10:19:51.800Z|00018|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2026-05-14T10:19:51.800Z|00019|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2026-05-14T10:19:51.800Z|00020|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2026-05-14T10:19:51.800Z|00021|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2026-05-14T10:19:51.800Z|00022|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2026-05-14T10:19:51.800Z|00023|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2026-05-14T10:19:51.800Z|00024|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2026-05-14T10:19:51.800Z|00025|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2026-05-14T10:19:51.800Z|00026|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2026-05-14T10:19:51.800Z|00027|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2026-05-14T10:19:51.800Z|00028|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 16, setting n-revalidator-threads to 5 2026-05-14T10:19:51.800Z|00029|ofproto_dpif_upcall|INFO|Starting 21 threads 2026-05-14T10:19:51.917Z|00030|bridge|INFO|bridge br-int: added interface br-int on port 65534 2026-05-14T10:19:51.917Z|00031|bridge|INFO|bridge br-int: using datapath ID 0000b2da02a1da54 2026-05-14T10:19:51.917Z|00032|connmgr|INFO|br-int: added service controller "punix:/var/run/openvswitch/br-int.mgmt" 2026-05-14T10:19:51.918Z|00033|bridge|INFO|ovs-vswitchd (Open vSwitch) 3.3.4 2026-05-14T10:19:52.366Z|00034|bridge|INFO|bridge br-ex: added interface br-ex on port 65534 2026-05-14T10:19:52.367Z|00035|bridge|INFO|bridge br-ex: using datapath ID 000022377870244b 2026-05-14T10:19:52.367Z|00036|connmgr|INFO|br-ex: added service controller "punix:/var/run/openvswitch/br-ex.mgmt" 2026-05-14T10:19:55.637Z|00037|connmgr|INFO|br-int<->unix#1: 18 flow_mods in the last 0 s (17 adds, 1 deletes) 2026-05-14T10:20:01.888Z|00038|memory|INFO|199664 kB peak resident set size after 10.1 seconds 2026-05-14T10:20:01.888Z|00039|memory|INFO|handlers:16 idl-cells-Open_vSwitch:199 ofconns:4 ports:2 revalidators:5 rules:26 2026-05-14T10:20:05.875Z|00040|connmgr|INFO|br-int<->unix#5: 18 flow_mods 10 s ago (17 adds, 1 deletes) 2026-05-14T10:20:29.888Z|00041|bridge|INFO|bridge br-int: added interface patch-br-int-to-provnet-b9670e09-282f-416c-9765-ce27f38efa19 on port 1 2026-05-14T10:20:29.888Z|00042|bridge|INFO|bridge br-ex: added interface patch-provnet-b9670e09-282f-416c-9765-ce27f38efa19-to-br-int on port 1 2026-05-14T10:21:05.875Z|00043|connmgr|INFO|br-int<->unix#5: 554 flow_mods in the 5 s starting 35 s ago (539 adds, 8 deletes, 7 modifications) 2026-05-14T10:31:48.657Z|00044|bridge|INFO|bridge br-int: added interface tap62e7095a-c5 on port 2 2026-05-14T10:31:50.910Z|00045|bridge|INFO|bridge br-int: added interface tap92983507-f0 on port 3 2026-05-14T10:31:58.709Z|00046|connmgr|INFO|br-int<->unix#5: 159 flow_mods in the 2 s starting 10 s ago (157 adds, 2 deletes)